01
China Suppliers Factory: Dujiang Jindun Steel Fireproof Doors for Superior Fire Resistance and Safety
Products Detail
Material: Steel-insulated fire-rated doors are crafted from premium galvanized steel sheets, with the door leaf filled with fire-rated insulation material.
Features: Reasonable structure, smooth and aesthetically pleasing surface, fire-rated, corrosion-resistant, and oxidation-resistant, effectively inhibiting fire spread.
Available Colors/Specifications: Customizable.
Opening Modes: Single-leaf, double-leaf, and unequal-leaf configurations.
Applications: High-end buildings, hotels, restaurants, hospitals, industrial plants, shopping centers, entertainment venues, etc.
Specialized Product: Extra-large steel fire-rated doors (3M x 3M), ideal for warehouses and industrial facilities, facilitating easy access for trucks.
Technical Specifications
| No. | Component Name | Model/Specification |
|---|---|---|
| 1 | Door Leaf | Material: 0.8mm galvanized steel plate |
| Thickness: 50mm | ||
| Core Material: High-density, environmentally friendly | ||
| Fireproof core board | ||
| 2 | Door Frame | Material: 1.2mm galvanized steel plate |
| Structure: One-time forming structure | ||
| 3 | Hinge Plate | Thickness: ≥3.0mm |
| 4 | Surface Treatment | Electrostatic powder spraying |
| Wood-grain transfer printing for surface finish | ||
| 5 | Fire Resistance Performance | Class A: ≥1.5 hours |
| Class B: ≥1.0 hour | ||
| Class C: ≥0.5 hour | ||
| 6 | Thermal Insulation Grade | Grade: 4 |
| 7 | Compliance Standard | GB12955-2015 Fireproof Door |
| 8 | Non-removable Component Thickness | Thickness: ≥1.2mm |
| 9 | Reinforced Structural | Thickness: ≥3.0mm |
| Component Thickness |
Product Features
Outstanding Fire Resistance
Manufactured according to National Standards, steel fire-rated doors come with various fire ratings (e.g., Class A, B, C), capable of withstanding high temperatures for over 210 minutes and effectively preventing fire spread.
Excellent Smoke Sealing
The sealed design of the door frame and leaf, along with high-temperature expansion sealing strips, ensures effective smoke control during a fire, reducing harm caused by toxic fumes.
Durable and Robust
Made with cold-rolled steel plates, offering high compressive and impact resistance while effectively withstanding external forces, thereby extending the service life.
Multi-Layer Structure Design
Filled with proprietary patented fireproof materials (e.g., magnesium oxide, magnesium chloride), enhancing fire resistance, corrosion resistance, and soundproofing for a balance between safety and comfort.
Aesthetic Appearance
Steel fire-rated doors can be customized with various surface treatments (e.g., powder coating, transfer printing) to blend seamlessly with diverse architectural and interior styles.
Convenient Installation & Maintenance
Professionally designed installation process for fast and easy setup; minimal maintenance required without complicated routines.
Structural Components
Door Frame
Made from cold-rolled steel, ensuring stability and safety.
Door Leaf
Typically consists of double-layered steel sheets filled with proprietary patented fireproof materials (e.g., magnesium oxide, magnesium chloride) for enhanced fire and corrosion resistance.
Sealing Strips
Positioned at the interface between the door frame and leaf; expands under high temperatures to block smoke and flame penetration.
Locks and Hinges
Equipped with high-temperature-resistant locks and hinges, ensuring smooth operation and enhanced security.
How to Choose the Right Steel Fire-Rated Door?
Choosing the appropriate steel fire-rated door is crucial for ensuring fire safety in buildings. Here are some key factors to consider:
Fire Rating
Understanding Fire Ratings: Based on National Standards, fire-rated doors are categorized into Class A (120 minutes), Class B (60 minutes), and Class C (30 minutes). Select the rating according to the building’s fire safety requirements.
Applications: For public spaces with high foot traffic, Class A doors are recommended. For general passageways or storage rooms, Class B or C may suffice.
Material and Structure
Door Leaf Material: Opt for high-strength cold-rolled or hot-rolled steel sheets for durability and impact resistance. Fireproof materials like rock wool enhance fire performance.
Sealing Design: Ensure proper sealing between the door frame and leaf. High-temperature expansion sealing strips significantly improve smoke and flame resistance.
Standards and Certifications
Check Certifications: Verify compliance with national and industry standards (e.g., Building Fire Protection Code, Steel Fire-Rated Doors). Request quality inspection reports from suppliers.
Brand Reputation: Prefer reputable brands known for quality and after-sales support.
Installation Requirements
Professional Installation: Ensure installation is performed by qualified professionals to maintain performance and sealing. Look for suppliers that offer installation services.
Compatibility: Confirm door dimensions align with the building’s door frame for proper fit.
Design and Aesthetics
Surface Treatment: Select finishes (e.g., coating, lamination) for visual appeal and corrosion resistance.
Color and Style: Match the door’s design to the overall architectural style for seamless integration.
Budget and Cost-Effectiveness
Price Considerations: Balance quality and cost. While high-quality fire-rated doors may have a higher upfront cost, they reduce long-term maintenance and replacement expenses.
Value for Money: Evaluate fire resistance, materials, installation services, and other features to select a cost-effective product.
After-Sales Service
Warranty Policies: Understand the warranty terms, including coverage duration and details.
Maintenance Support: Choose suppliers offering regular maintenance and inspection services to ensure long-term safety.
By considering factors such as fire rating, materials, installation, design, budget, and after-sales support, you can confidently select a steel fire-rated door tailored to your needs, ensuring safety for life and property.
Frequently Asked Questions (FAQ)
What are the primary differences between Class A, B, and C fire-rated doors?
Class A doors provide fire resistance for at least 1.5 hours (or up to 120 minutes) and are recommended for critical exits and high-traffic public areas. Class B offers at least 1.0 hour (60 minutes) of protection, suitable for general hallways and corridors. Class C provides 0.5 hours (30 minutes), ideal for maintenance rooms, shafts, and low-risk zones.
Can extra-large steel fire-rated doors be customized for industrial warehouses?
Yes. Customized extra-large configurations, including 3M x 3M oversized dimensions, are specifically engineered for industrial plants, factories, and logistics warehouses to allow unobstructed vehicle and freight access while preserving certified structural fire protection.
How do high-temperature intumescent sealing strips work in a fire?
The intumescent perimeter seals expand dramatically when exposed to elevated heat. This expansion hermetically closes the gap between the door frame and leaf, stopping toxic fumes, suffocating smoke, and direct flame roll-over from penetrating adjacent compartments.
What finishes are available to match contemporary interior designs?
Steel fire doors can be customized with heavy-duty electrostatic powder coatings in custom RAL shades or wood-grain thermal transfer prints. This allows seamless architectural integration with commercial lobbies, hotels, corporate offices, and modern hospital corridors.
What core materials provide the highest thermal insulation and stability?
Our door leaves utilize high-density, eco-friendly patented fireproof core boards made with magnesium oxide and magnesium chloride, or rock wool composites. These non-combustible materials deliver Grade 4 thermal insulation and superior structural resistance without degrading under thermal stress.
How often should steel fire-rated doors be inspected and maintained?
Fire doors should undergo routine operational and visual inspections at least every 6 to 12 months. Periodic checks ensure that self-closing mechanisms latch securely, clearances meet tolerance limits, and intumescent gaskets and hinges remain undamaged.