Leave Your Message
Stainless Steel Glass Fire Rated Door - High-Quality Solution from China Suppliers and Factory
Hot Products
Products Categories
Featured Products

Stainless Steel Glass Fire Rated Door - High-Quality Solution from China Suppliers and Factory

Discover our premium fire-resistant glass doors, crafted with high-quality 304 stainless steel frames as the foundation. These doors expertly blend robustness and transparency, making them an ideal choice for modern architecture. Our stainless steel frames are not only corrosion-resistant but also require minimal maintenance, ensuring longevity and durability. For the glass, opt for our high-transparency nano-silicon fire-resistant glass, which adheres to stringent fire protection standards. This combination of safety and aesthetics aligns perfectly with contemporary design principles, catering to both illumination and security needs. As a leading factory and supplier in China, we pride ourselves on delivering exceptional products that meet the highest standards of quality. Upgrade your space with our stylish and reliable fire-resistant doors today!

    Product Features

    Stainless Steel Glass Fire Rated Door (2)

    Fire Resistance Performance

    The door leaf is filled with our self-developed fire-resistant core material, while an intumescent fire-sealing strip between the door frame and the leaf expands under high temperatures to block flame penetration. This structure ensures the steel fire-rated door maintains its thermal insulation performance and meets fire resistance requirements across all rating levels.

    advantage-2

    Smoke Sealing

    The door gap is precisely controlled within 1–3 mm and paired with a door closer to ensure the door remains closed. The fire-sealing strip stays flexible at normal temperatures and expands under heat to tightly seal gaps, effectively preventing the spread of toxic smoke.

    advantage-2

    Durability & Strength

    Constructed from high-grade 304 stainless steel, both the frame and door leaf offer superior corrosion and wear resistance, standing up to humidity, heat, and harsh environments. The reinforced door structure provides excellent impact resistance and long-term stability — resisting deformation or cracking without frequent maintenance — ensuring durability and safety over years of use.

    advantage-2

    Aesthetic Appearance

    It retains metallic properties while conveying natural textures, and can even be customized with special tones (such as bronze, black plating) according to requirements, breaking the single tone of traditional stainless steel and creating an echo or contrast with the main color of the space. The glass has excellent light-gathering performance, enabling our stainless steel glass fire-resistant doors to fit diverse styles such as modern and minimalist, and integrate both lighting function and design sense.

    advantage-2

    Installation & Maintenance

    The frame is fixed with expansion bolts, and the gap between the frame and wall is filled with cement mortar for stability. Routine maintenance is simple—regularly check the hardware for flexibility, clean the sealing strips, and replace any damaged components individually—ensuring a longer service life for the steel fire-rated door.

    advantage-2

    Fire Rating

    Grade C Fire integrity ≥ 30 minutes, fire insulation ≥ 30 minutes

    Grade C

    Fire integrity ≥ 30 minutes, fire insulation ≥ 30 minutes; Suitable for secondary fire protection areas such as pipe shafts and cable shafts, mainly used to block the spread of small fires.

    Grade B Fire integrity ≥ 60 minutes, fire insulation ≥ 60 minutes

    Grade B

    Fire integrity ≥ 60 minutes, fire insulation ≥ 60 minutes; Suitable for areas with moderate fire protection requirements such as stairwells, antechambers, and evacuation routes.

    Grade A Fire integrity ≥ 90 minutes, fire insulation ≥ 90 minutes

    Grade A

    Fire integrity ≥ 90 minutes, fire insulation ≥ 90 minutes; Suitable for important areas such as fire control rooms, power distribution rooms, rooms with valuable equipment, and fan rooms.

    Others Fire integrity ≥ 120-180 minutes, fire insulation ≥ 120-180 minutes

    Others

    Fire integrity ≥ 120-180 minutes, fire insulation ≥ 120-180 minutes; Suitable for areas with ultra-Class A fire protection requirements such as chemical workshops, tunnel escape exits, and arms and ammunition depots.

    Application Areas

    Industrial Facilities

    Industrial Facilities

    Public Institutions (Hospitals Schools)

    Public Institutions (Hospitals / Schools)

    Commercial Buildings

    Commercial Buildings (Offices / Hotels / Residences)

    Steel Fire Rated Door

    Transportation Hubs (Airports / Rail Stations)

    Military and Security Facilities

    Military and Security Facilities

    Frequently Asked Questions

    Q: What is the fire resistance performance of these doors?

    Our doors feature a self-developed fire-resistant core material and intumescent fire-sealing strips that expand under high temperatures. This design prevents flame penetration and maintains thermal insulation across various rating levels (Grade A, B, C, and others).

    Q: How do the doors prevent smoke transmission?

    The door gaps are precisely controlled within 1–3 mm and paired with automatic door closers. Additionally, the fire-sealing strips expand under heat to tightly block any gaps, effectively preventing toxic smoke from spreading.

    Q: What materials are used to construct these fire-rated doors?

    Both the frame and door leaf are made from high-grade 304 stainless steel, which offers exceptional wear and corrosion resistance. The core is filled with a specialized fire-resistant insulating material.

    Q: Can the appearance of the stainless steel doors be customized?

    Yes, the doors can be customized with special tones such as bronze or black plating to match the design of your space. They combine metallic durability with aesthetic glass integration for a modern, minimalist look.

    Q: How are these doors installed and maintained?

    The door frame is secured with expansion bolts and the gap is filled with cement mortar. Maintenance is straightforward: periodically inspect hardware flexibility, clean the sealing strips, and replace components individually if necessary.

    Q: Where are these fire-rated doors typically used?

    They are suitable for various sectors including industrial facilities, public institutions (hospitals and schools), commercial spaces (offices, hotels, residences), transportation hubs (airports and rail stations), and military or security complexes.

    Contact Us

    Leave Your Message